Testing Procedures Completed

Type: Exploratory/Comparison
Stage: Primary
State of Solution: pre-construction
Conditions: Materials have not been gathered. This is not a physical test.
Parameter/Specification: Which method of desalination is most suited to the problem situation?
Tools and Equipment: Computer, Internet, Notepad program
Procedure: 1. Google types of desalination, make a list
                   2. Google each type of desalination, take careful notes
                   3. Compare the desalination types against each other and against the specifications of the problem situation.
                   4. Make a decision re: which type of desalination to use in the final solution.
Target: The cheapest, most low-maintenence and high-yield method of desalination

End Result: Solar humidification was pinpointed as the ideal method for this device due to its ubiquity and low energy uptake.

Type: Assessment:

Stage: Primary
State of Solution: All Materials acquired, unassembled.
Conditions: Water will be used, equipment should expect to get wet. This is testing how well water will condense on the plastic cone being used.
Parameter/Specification: Condensation Efficiency/Time
Tools and Equipment: Black Plastic cone, water, bucket, timer
Procedure: 1. Stretch clear plastic sheet over bucket filled with water
                  2. Heat water by putting it under a direct heat source
                  3. Start a timer and check back every fifteen minutes. Mark when water first appears on plastic and when plastic is completely covered. After two hours, report on formation of droplets.
Target: <1 hr for appearance of condensation, <1.5 hr for complete coverage, <2 hrs for droplet formation
End Result: The clear plastic was covered with a thin sheen of condensed water after 1.5 hours. Water first started appearing on the plastic in sparse amounts after 45 minutes. After two hours, the droplets were large enough that disturbing the plastic sheet by tapping on it would cause droplets to fall back into the reservoir.

Monday, August 29, 2011

Testing Procedures: Team

 Introduction:
       Our final solution is expected to quickly and efficiently remove all presence of salt and bacteria from the input water, making it sufficiently potable for human consumption. It is expected to do this without compromising the volume of the water added, and it should not need inordinate maintenence.
Our specifications require that the device not only desalinate and purify the water, but that it should do so in an efficient and streamlined manner, in order to meet the goal of instilling confidence and self-autonomy in the customers. Thus, we will not only be testing the chemical parameters of the output water, but testing the volumes of the input and output, and determining productivity.
       We will be testing three main parameters - Salinity, Bacteria Content, and Efficiency - at different stages of development. GMG will test her desalination component on its own before connecting it to the other components of the project for further testing, and the other team members will do the same with their components. GMG will conduct all salinity-parameter tests, EK will conduct efficiency tests, and EH will conduct the bacteria content tests, as per their roles in the team. Aesthetics tests will be assessed via a user survey administered at the end of the construction and testing process. The survey will not only assess the effectiveness of the unit, but also the user's feelings on it regarding it's aesthetics and general mood.
The unit will be tested where it is being built - the MAST systems lab. The desalination component will be tested on its own, outside, and the other components (and the final product) will be tested inside, in alignment with where they would be expected to function in the problem situation. The unit will be constantly running, even during testing (except for efficiency testing), which will not affect the chemistry of the water.Parameters will be tested at a sea-level, moderately humid environment. The air of the intended location of usage is much drier, but atmospheric humidity should not adversely affect too much of the process, except for perhaps slowing down the rate of evaporation and therefore the process entirely. However, since it is not feasible to go to a desert to test this equipment, compensations must be made.

(Bolded entries are the jurisdiction of GMG. Underlined Italicized entries are the jurisdiction of EH. Standard entries are the jurisdiction of EK)

Type: Exploratory/Comparison
Stage: Primary
State of Solution: pre-construction
Conditions: Materials have not been gathered. This is not a physical test.
Parameter/Specification: Which method of desalination is most suited to the problem situation?
Tools and Equipment: Computer, Internet, Notepad program
Procedure: 1. Google types of desalination, make a list
                   2. Google each type of desalination, take careful notes
                   3. Compare the desalination types against each other and against the specifications of the problem situation.
                   4. Make a decision re: which type of desalination to use in the final solution.
Target: The cheapest, most low-maintenence and high-yield method of desalination

Type: Exploratory/Comparison
Stage: Primary
State of Solution: pre-construction
Conditions: Materials have not been gathered. This is not a physical test.
Parameter/Specification: Which method of water purification is most suited to the problem situation and the chosen method of desalination?
Tools and Equipment: Computer, Internet, Notepad program
Procedure: 1. Google types of water purification, make a list
                   2. Google each type of water purification, take careful notes
                   3. Compare water purification methods against each other, against the chosen desalination method, and against the specifications of the problem situation.
                   4. Make a decision re: which type of water purification to use in the final solution.
Target: The cheapest, most low-maintenence and easiest to implement type of water purification, that works in tandem with the chosen desalination method.

Type: Exploratory/Comparison
Stage: Preliminary
State of Solution: Preconstruction
Conditions: Preconstruction
Parameter/Specification: Which green energy source would be most useful and practical for the unit?
Tools and Equipment: Computer with internet capabilities
Procedure:
  1. Search the internet for information about various types of green energy sources
  2. Compare and contrast different types
  3. Pick an energy source to use
Target: Determine which energy source would be practical for our project.

Type: Exploratory
Stage: Preliminary
State of Solution: The solution is stationary and off.
Time: Before starting to build
Tools: Calculator, materials, ruler
Tester: EK
  1. Count up all the expenses i.e. the materials, the power.
  2. Make sure the desalination unit us under $300.
  3. Check to make sure the desalination unit is weather proof by checking all visible materials and only using those which can be exposed to high temperature, high wind speeds, and water.
  4. Make sure that none of the materials or parts that are going to be constructed are fragile.
  5. Test every material for leaks before using them.
  6. Make sure that the desalination unit dimensions are suitable to an average Chile household.
  7. Make sure dimensions are less than 2m by 2m.  


Type: Exploratory/Comparison
Stage: Secondary
State of Solution: Preconstruction
Conditions: Preconstruction
Parameter/Specification: Determine which photovoltaic cells, solar panel brand, size, and watts we should use for our project, and purchase one.
Tools and Equipment: Computer with internet capabilities
Procedure:
  1. Search the internet for different types of solar panels
  2. Compare and contrast different types and prices
  3. Select  a solar panel to buy
Target: Choose and secure a solar panel to use for the project.


A large graduated cylinder
Type: Assessment:
Stage: Primary
State of Solution: All Materials acquired, unassembled. Black plastic should be shaped into a cone
Conditions: Water will be used, equipment should expect to get wet. This is testing how well water will condense on the plastic cone being used.
Parameter/Specification: Condensation Efficiency/Time
Tools and Equipment: Black Plastic cone, water, bucket, timer
Procedure: 1. Suspend black plastic cone over bucket filled with water
                  2. Heat water, either by putting it in the sun or over a direct heat source
                  3. Time how long it takes for water to condense on black plastic, and how long it takes to start dripping off the tip of the cone.
Target: <1 hr

Type: Comparative
Stage: Secondary
State of Solution: Stationary, off.
Time: Before starting to build.
Tools: Bucket, beaker, Tubes, Spigots, Plastics, water
Tester: EK

  1. Compare materials against each other.
  2. Check the tubing for holes or leaks.
  3. Pour water through one tube into a bucket.
  4. Pour water through a second tube into a bucket.
  5. Measure to see which tube had a better retention rate.
  6. Time to see which tube was faster.
  7. Measure to see which tube is longer.
  8. Check the ends of each tube to see which is easier to attach.
  9. Do the same with the different plastics that are to construct the desalination unit.
  10. Check the spigot for leaks and holes.
  11. Fasten the spigot onto a sink to make sure that it works.
  12. Make sure the water flows smoothly.
  13. Make sure the spigot is easy to turn on and off.
Type: Assessment
Stage: Secondary
State of Solution: Stationary, unconnected from storage unit, mid-production.
Conditions: time-sensitive, water will be dealt with.
Parameter/Specification: Desalination Efficiency/Time
Tools and Equipment: bucket, timer, graduated cylinder or beaker
Procedure:  1. Measure 2 L of saltwater prior to desalination using a graduated cylinder or beaker
                   2. Place in input tank, place in sun, begin desalination. Start timer
                   3. When all water has left input tank and is either in vapor form, condensed on the cone, or liquid in the bucket, stop the timer.
Target: <2 hrs

Type: Assessment
Stage: Secondary
State of Solution: Stationary, unconnected from storage unit, mid-production.
Conditions: Water will be used in test, equipment should expect to get wet.
Parameter/Specification: Bacteria Content
Tools and Equipment: Coliert-18, bucket, test tube, pipette
Procedure: 1. Add saltwater to desalination component of solution
                  2. Place in sun to start distillation.
                  3. Place bucket beneath outflow pipe to collect condensed fresh water
A Coliert-18 Matrix
                  4. When water has reached appropriate levels (this may take a few hours), take a sample of water in a test tube
                  5. Add an appropriate amount of Coliert-18 to test tube, measure hue change
Target: No Bacteria Present, no hue change

Type: Assessment
Stage: Tertiary
State of Solution: During Construction
Conditions: Stationary, Outside, On
Parameter/Specification: Ensure that the solar panels generate enough energy to run the UV lights.
Tools and Equipment: Wattmeter
Procedure:
1.      Use a wattmeter to measure the amount of out put the solar panel generates.
2.      Compare to the number of watts need to run the UV lights
Target: Ensure that the solar panels function properly.


Type: Assessment
Stage: Tertiary
State of Solution: Stationary, unconnected from storage unit, mid-production.
Conditions: Water will be used in test, equipment should expect to get wet.
Parameter/Specification: Salinity
Tools and Equipment: Refractometer, bucket
Procedure: 1. Add saltwater to desalination component of solution
                  2. Place in sun to start distillation.
                  3. Place bucket beneath outflow pipe to collect condensed fresh water
                  4. When water has reached appropriate levels (this may take a few hours), dip refractometer into bucket, wetting the testing slide.
                  5. Hold refractometer up to a light source, and assess level of salt content.
Target: 0-500ppm

Type: Assessment
Stage: Tertiary
State of Solution: Stationary, on.
Time: After built.
Tools: Salt water, beaker, bucket, timer
Tester: EK

  1. Measure out 40L of salt water.
  2. Pour water into desalination unit.
  3. Start Timer.
  4. End Timer.
  5. Measure the amount of clean water that is in the storage chamber.
  6. Subtract the amount of clean water from the amount of salt water poured in to find the water retention rate.
  7. Measure the amount of clean water it produces in one day.
  8. Make sure it is at least 40L.


An Atago Refractometer
Type: Validation
Stage: Tertiary
State of Solution: Stationary, Fully constructed and Active
Conditions: time-sensitive, water will be dealt with.
Parameter/Specification: Device Efficiency
Tools and Equipment: Graduated cylinder
Procedure:  1. Measure a fixed volume of saltwater prior to desalination using a graduated cylinder or beaker
                   2. Place in input tank, place in sun, begin desalination.
                   3. 1 day later, measure volume of freshwater after desalination using same method, compare with original volume.
Target: 90-95% volume retained

Type: Validation
Stage: Tertiary
State of Solution: Stationary, Fully constructed and Active
Conditions: time-sensitive, water will be dealt with, equipment will get wet
Parameter/Specification: Bacteria Content
Tools and Equipment: Coliert-18, test tube, pipette
Procedure:  1. Add saltwater to input tank of desalination unit.
         2. Wait 1 day, then collect a sample of water from the storage tank with the test tube.
         3. Add appropriate amount of Coliert-18 to water, wait 18 hours, measure hue change
Target: No hue change, no bacteria present.

Type: Validation
Stage: Quaternary
State of Solution: Post-construction
Conditions: Stationary, Outside, On
Parameter/Specification: Are the electrical components working?
Tools and Equipment: Wattmeter
Procedure:
  1. Check the wiring, the electricity should be transferring from the solar panel to the UV lights.
  2. Check the UV light, they should be burning brightly and not flickering.
  3. Check the solar panel, the photovoltaic cells should be generating energy.
Target: Guarantee that the electrical components of the unit are functioning correctly.

Type: Validation
Stage: Quaternary
State of Solution: Stationary, Fully constructed and Active
Conditions: time-sensitive, water will be dealt with, equipment will get wet
Parameter/Specification: Salinity
Tools and Equipment: Refractometer, beaker
Procedure:  1. Add saltwater to input tank of desalination unit.
         2. Wait 1 day, then collect a sample of water from the storage tank with the beaker.
         3. Dip refractometer into sample, wetting the testing surface.
         4. Hold refractometer up to light source and assess the level of salt content.
Target:0-500 ppm

Type: Validation
Stage: Quaternary
State of Solution: Stationary, off.
Time: After built
Tools: Surveys, pencils, sample group of individuals
Tester: EK

1. Check aesthetics.
2. Give out survey to various individuals.
3. Ask individuals to take survey.
4. Collect survey.
5. Review results.
6. Fix desalination unit to adhere to suggestions of the surveyed. 
_____________________________________
Sources:

Blaster's Tool and Supply Company. Graduated Cylinder 100 mL. (2011). Retrieved 02 October 2011 from http://www.blasterstool.com/graduatedcylinder100ml-2.aspx

Idexx. Coliert-18. (2011). Retrieved 02 October 2011 from http://www.idexx.com/view/xhtml/en_us/water/colilert-18.jsf

NME National Microscope Exchange. Salinity Refractometers. (2011). Retrieved 02 October 2011 from https://www.nationalmicroscope.com/salinity-refractometers-c-29_57.html

Testing Procedures: Individual

  Introduction:
       My component of our final solution is expected to quickly and efficiently remove all presence of salt from the input water, making it sufficiently potable for human consumption. My responsibility was to choose a reliable and fitting form of desalination and implement the section of the device responsible for the desalination.
My personal require only that the device desalinate the water, and that it should do so in an efficient and streamlined manner, in order to meet the goal of instilling confidence and self-autonomy in the customers. Thus, my personal tests deal mainly with the chemical parameters of the output water.
        I will test my desalination component on its own before connecting it to the other components of the project for further testing, and the other team members will do the same with their components. The unit will be tested where it is being built - the MAST systems lab. The desalination component will be tested on its own, outside, in alignment with where it would be expected to function in the problem situation. Even when it is connected to the storage unit, the main desalination component will remain outside. The unit will be constantly running, even during testing, which will not affect the chemistry of the water. Parameters will be tested at a sea-level, moderately humid environment. The air of the intended location of usage is much drier, but atmospheric humidity should not adversely affect too much of the process, except for perhaps slowing down the rate of evaporation and therefore the process entirely. However, since it is not feasible to go to a desert to test this equipment, compensations must be made.



Type: Exploratory/Comparison
Stage: Primary
State of Solution: pre-construction
Conditions: Materials have not been gathered. This is not a physical test.
Parameter/Specification: Which method of desalination is most suited to the problem situation?
Tools and Equipment: Computer, Internet, Notepad program
Procedure: 1. Google types of desalination, make a list
                   2. Google each type of desalination, take careful notes
                   3. Compare the desalination types against each other and against the specifications of the problem situation.
                   4. Make a decision re: which type of desalination to use in the final solution.
Target: The cheapest, most low-maintenence and high-yield method of desalination

Type: Assessment:
Stage: Primary
State of Solution: All Materials acquired, unassembled. clear plastic should be shaped into a cone
Conditions: Water will be used, equipment should expect to get wet. This is testing how well water will condense on the plastic cone being used.
Parameter/Specification: Condensation Efficiency/Time
Tools and Equipment: Black Plastic cone, water, bucket, timer
Procedure: 1. Suspend black plastic cone over bucket filled with water
                  2. Heat water, either by putting it in the sun or over a direct heat source
                  3. Time how long it takes for water to condense on black plastic, and how long it takes to start dripping off the tip of the cone.
Target: <1 hr

Type: Assessment
Stage: Secondary
State of Solution: Stationary, unconnected from storage unit, mid-production.
Conditions: time-sensitive, water will be dealt with.
Parameter/Specification: Desalination Efficiency/Time
Tools and Equipment: bucket, timer, graduated cylinder or beaker
Procedure:  1. Measure 2 L of saltwater prior to desalination using a graduated cylinder or beaker
                   2. Place in input tank, place in sun, begin desalination. Start timer
                   3. When all water has left input tank and is either in vapor form, condensed on the cone, or liquid in the bucket, stop the timer.
Target: <2 hrs

Type: Assessment
Stage: Tertiary
State of Solution: Stationary, unconnected from storage unit, mid-production.
Conditions: Water will be used in test, equipment should expect to get wet.
Parameter/Specification: Salinity
Tools and Equipment: Refractometer, bucket
Procedure: 1. Add saltwater to desalination component of solution
                  2. Place in sun to start distillation.
                  3. Place bucket beneath outflow pipe to collect condensed fresh water
                  4. When water has reached appropriate levels (this may take a few hours), dip refractometer into bucket, wetting the testing slide.
                  5. Hold refractometer up to a light source, and assess level of salt content.
Target: 0-500ppm

Type: Validation
Stage: Quaternary
State of Solution: Stationary, Fully constructed and Active
Conditions: time-sensitive, water will be dealt with, equipment will get wet
Parameter/Specification: Salinity
Tools and Equipment: Refractometer, beaker
Procedure:  1. Add saltwater to input tank of desalination unit.
         2. Wait 1 day, then collect a sample of water from the storage tank with the beaker.
         3. Dip refractometer into sample, wetting the testing surface.
         4. Hold refractometer up to light source and assess the level of salt content.
Target:0-500 ppm

NEXT

Testing Survey

Desalination Unit Survey
MAST Systems Engineering 2 – Assessment of Effectiveness of Home Desalination Unit
GMG, EK, EH


Did the desalination unit remove all salt and bacteria from the water?

                       

How long did it take to produce one litre of water?

                       

Were there any major problems that required maintenance during the desalination process? If so, explain
                        ___________________________________________________________________________________
___________________________________________________________________________________
___________________________________________________________________________________
_________________________________

On a scale of one to ten, how unobtrusive and/or attractive is the unit?  _______ 

Would you keep it in your home permanently? __________________

Circle any of the following words that describe how you would feel if this desalination unit was a part of your daily life

Burdened                     Confident                     Safe                 Hassled                        Stupid

Independent                 Unchanged                   Free                 Annoyed                      Happy


Circle any of the following words that describe this unit, in your eyes.

Efficient                        Streamlined                  Ugly                 Bulky                   Unobtrusive

Productive                    Inefficient                      Pointless           Unworkable                 Useful


Do you have any suggestions on making this project better?

___________________________________________________________________________________
___________________________________________________________________________________
___________________________________________________________________________________
_______________________________________